Solution

Intelligent RAID protection, built for SSD storage.

maxRAID re-engineers data protection from the ground up for NVMe and SSD arrays — enterprise-grade redundancy without the performance tax.

  • Rebuilds in minutes instead of days
  • Wear-aware, distributed rebuilds
  • Full NVMe-native performance
  • 20% or less capacity overhead

Free storage design session

30 minutes with an NVMe expert. No obligation.

We reply within one business day. No newsletter, no spam.

The problem

Classic RAID was built for hard drives

Classic RAID was architected around the physics of hard drives: slow mechanical seeks, predictable latency, and rebuilds that take hours because disks simply can’t go faster.

maxRAID re-engineers data protection from the ground up for NVMe and SSD arrays — delivering enterprise-grade redundancy without the performance tax. Protect your data at the speed your storage was built to run.

NVME ARRAYOnlineOnlineOnlineRebuildingOnlineOnlineDataParityRebuild in progress

Why classic RAID fails on flash

1

Rebuilds that protect drives now destroy them

When an HDD fails, rebuilding is a read-intensive job. With SSDs, a rebuild rewrites terabytes of data across surviving drives in minutes, burning through precious program/erase (P/E) cycles. A protection mechanism that wears out your remaining healthy drives is protection that backfires.

2

The bottleneck moved from mechanical to architectural

HDD RAID could lean on sequential I/O to hide mechanical latency. Flash has no seek penalty — but legacy RAID engines can’t feed NVMe’s parallelism. Single-threaded parity computation and lock-based I/O paths turn 7 GB/s drives into arrays that deliver a fraction of their potential. The RAID engine becomes the bottleneck, not the storage.

3

The economics inverted

RAID trade-offs (stripe size, hot spare count, redundancy overhead) were tuned for cheap, slow, disposable disks. Flash is expensive and endurance-limited — every redundant write and every inefficient parity update spends SSD lifespan that translates directly into money.

What is needed instead

RAID redesigned around flash physics: distributed rebuilds that minimise writes, parallel NVMe-native data paths, and intelligence that treats endurance as a resource to protect expensive flash-based NVMe SSDs.

What intelligent RAID protection delivers

maxRAID 5 re-engineers protection for flash, with distributed, wear-aware rebuilds that complete in minutes instead of days, while sustaining full NVMe-native performance at just 20% or less overhead in capacity.

80 %5 × 4 TB → 16 TB usable
87.5 %8 × 8 TB → 56 TB usable

More about the software on the WildFire Storage maxRAID page.

How we work

From first call to running system

No one buys storage infrastructure on the first visit. We make the first step small and the rest predictable.

Free design session

Thirty minutes with an NVMe architect. We map your workload, capacity, performance targets and the constraints of your environment.

Validated design

You receive a sized configuration with a TCO comparison, pre-validated hardware and software, and a proof-of-concept plan if you want to test first.

Turnkey delivery

Pre-configured systems delivered and installed, with vendor support contracts in place. One contact for the whole stack.

Buying new NVMe SSD’s? Calculate your TCO in 2 minutes.

Open the TCO calculator
Call us Plan a call